Reversing Pump

Reversing pumps are used when hydraulic steering is fitted on boats up to 65 feet L.O.A. (depending on rudder torque). The pumps are switched on by the automatic pilot and make a steering correction to left or right determined by the direction of rotation of the pump motor. The motors are of the permanent magnetic type and reversing direction is accomplished by reversing the motor input current.

The pump has only three moving parts and requires no complicated check valves to prevent rudder movement when de-energized. Output flow is completely adjustable to 50% of rated flow allowing the pump output to be adjusted precisely to the volume of steering cylinder fitted. The pump is exceptionally reliable and delivers more than twice the hydraulic output per watt of input than gear pumps manufactured by competitors.

Motors are heavy duty, a full 85 mm in diameter with long brushes and sealed ball bearings for long service life. The molded rubber mounting foot can be rotated to allow the pump to be mounted on any surface.

A useful range of accessories can be used to enhance the pump by incorporating added valves and solid state FET switching. The valves mount directly to the pump body. The FET switch mounts adjacent to the pump. No other autopilot pump made offers such advantages.

Benefits of the Octopus Reversing Pumps

Piston pump technology giving higher efficiency and accuracy Fewer moving parts giving increased reliability Variable flow rate to make sure the pump is matched as accurately as possible to the manual steering system Professional cut off valves for simple servicing.

Specifications and Dimensions

Pump Model

Dimensions (mm)
Volts
Flow Per Minute
Maximum Pressure

Average* Current draw(amps)

Peak
Current (amps)
A
B
C
D.C.
cu. cm.
cu. in.
bar
Psi
1012
195
114
100
12
1000
60
70
1000
7-8
25
1024
220
114
100
24
1000
60
70
1000
3-4
12
1212
195
114
100
12
1200
72
70
1000
7-8
25
1224
220
114
100
24
1200
72
70
1000
3-4
12
2012
220
114
100
12
2000
120
55
800
7-8
25
2024
220
114
100
24
2000
120
60
900
3-4
12

Installation

The pump set should be mounted on a horizontal surface in a clean dry area. The three hydraulic connections to the steering system should be made using tubing, which meets the steering system manufacturer's specification. All three hose connections must be used and under no circumstances must the pump set be run without the compensating (breather) line connected to the steering system reservoir.


 

Optional Accessories
Shut Off Valve SV The shut off valve mounts on the end of the pump enabling the pump unit to be disconnected from the steering system without loss of hand steering.
By-Pass Valve BP12V (12 volt) BP24V (24 volt) The bypass valve can be mounted to the pump and consists of a normally open solenoid valve (which is connected across the pump output) and a translucent plastic reservoir. When the valve is mounted to the pump and the assembly connected to a balanced hydraulic cylinder, the cylinder can be used to drive the rudder on vessels with mechanical steering. No external reservoir is required. Built-in bleeder screws allow the unit to be quickly filled and purged.
Unbalanced Valve UB The unbalanced valve fits on the pump to adapt flow to unbalanced steering cylinders.

Note: For larger pump sizes see our product information sheets on Continuous Running Pump sets CRA and CRB.

Part Number Descriptions

Adjustable Displacement Reversing Pump with - Shut Off Valve - 1/4 NPT Ports

OCTAF101217141 1000cc/min - 12 VOLT
(80-280cc CYLINDER)
Peak current 19 Amps Normal current|
6-8 Amps
OCTAF102417141 1000cc/min - 24 VOLT
(80-280cc CYLINDER)
Peak current 10 Amps Normal current
3-4 Amps
OCTAF121217141 1200cc/min - 12 VOLT
(100-350cc CYLINDER)
Peak current 19 Amps Normal current
6-8 Amps
OCTAF122417141 1200cc/min - 24 VOLT
(100-350cc CYLINDER)
Peak current 10 Amps Normal current
3-4 Amps
OCTAF201217141 2000cc/min - 12 VOLT
(250cc-460cc CYLINDER)
Peak current 22 Amps Normal current
7-9 Amps
OCTAF202417141 2000cc/min - 24 VOLT
(250cc-460cc CYLINDER)
Peak current 11 Amps Normal current
4-5 Amps

*Specifications subject to change without notice.

Note: The price is subject to change at any time without any notice. Not responsible for any typographical errors. Any products can be cancelled from sale at any time.
  • All products sold here come with Full Manufacturer's Warranty
  • Email us at
  • [email protected] for any quesitons
  • WarningWARNING: This product can expose you to chemicals including Di-n-hexyl Phthalate, DnHP, which is known to the State of California to cause reproductive harm, and Vinyl Chloride which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.

Be the first to write a review for this product

Browse for more products in the same category as this item:

Autopilot > ComNav Autopilot > ComNav Autopilot Drive Unit